ACS724LLCTR-20AU-T
Allegro MicroSystems
- Lifecycle
- Active
- Stock
- 4933 PCS
- Package
- SOIC-8
- Series
- Current Sensors
This in-depth comparison of the ACS724LLCTR-20AU-T and ACS723LLCTR-05AB-T provides valuable insights into their specifications and key features. We cover important factors in detail, including RoHS compliance, REACH status, series, mounting style, package type, and other relevant characteristics. Presenting the differences side by side simplifies component selection, making it easier for you to select the best option for your specific application.
Replacement verdict
The ACS724LLCTR-20AU-T is not a direct drop-in replacement for the ACS723LLCTR-05AB-T due to differences in current sensing range, output type, and package construction, but it can serve as a functional substitute in applications where a higher current range and unidirectional sensing are acceptable. Design validation is required to confirm compatibility with the target circuit.
Allegro MicroSystems
Allegro MicroSystems
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ACS723LLCTR-05AB-T | ACS724LLCTR-20AU-T | Why it matters |
|---|---|---|---|
| Current Sensing Range | ±5 A | ±20 A | Defines the maximum measurable current; a ±20 A sensor cannot be directly substituted where ±5 A full-scale resolution is required, and vice versa. |
| Sensitivity | 400 mV/A | 100 mV/A | Determines the output voltage swing per amp; different sensitivity changes the ADC scaling and effective resolution in the application circuit. |
| Output Type | Analog, bidirectional | Analog, unidirectional | Bidirectional parts measure both positive and negative current, while unidirectional parts only measure one polarity, affecting circuit topology and signal conditioning. |
| Supply Voltage | 4.5 V to 5.5 V | 4.5 V to 5.5 V | Both operate from a 5 V rail, so power supply compatibility is maintained between the two devices. |
| Isolation Voltage | 2.1 kVrms | 2.1 kVrms | Rated isolation between the current path and signal side; identical ratings mean safety and creepage requirements are equivalent. |
| Bandwidth | 80 kHz | 120 kHz | Higher bandwidth allows faster current transient tracking; a mismatch can affect control loop response in motor or power conversion designs. |
| Package | 8-lead SOIC | 8-lead SOIC | Identical footprint and pinout enable drop-in PCB compatibility without layout changes. |
| Operating Temperature Range | -40 °C to 150 °C | -40 °C to 150 °C | Matching temperature ratings ensure both parts are suitable for the same industrial and automotive thermal environments. |
| Typical Accuracy | ±3% | ±1.5% | Accuracy affects measurement error budget; the ACS724 offers tighter accuracy, which may be required for precision current monitoring. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ACS724LLCTR-20AU-T | ACS723LLCTR-05AB-T |
|---|---|---|
| Part Status | Active | Active |
| For Measuring | DC | AC/DC |
| Sensor Type | Hall Effect, Open Loop | Hall Effect, Open Loop |
| Current - Sensing | 20A | 5A |
| Number of Channels | 1 | 1 |
| Output | Ratiometric, Voltage | Ratiometric, Voltage |
| Sensitivity | 200mv/A | 400mV/A |
| Frequency | 120kHz | DC ~ 80kHz |
| Linearity | ±1.5% | ±1% |
| Accuracy | ±0.7% | ±3% |
| Voltage - Supply | 4.5V ~ 5.5V | 5V |
| Response Time | 4µs | 5µs |
| Current - Supply (Max) | 14mA | 14mA |
| Operating Temperature | -40°C ~ 150°C | -40°C ~ 150°C |
| Polarization | Unidirectional | Bidirectional |
| Mounting Type | Surface Mount | Surface Mount |
The ACS723LLCTR-05AB-T is a bidirectional, 5 A full-scale current sensor with an analog output, while the ACS724LLCTR-20AU-T is a unidirectional, 20 A full-scale current sensor with an analog output. They differ in measurement range, directionality, and sensitivity.
Yes. Both devices are offered in the same SOIC-8 package with the same pinout, allowing for a common PCB footprint. However, external component values and firmware thresholds may need adjustment due to different sensitivities and measurement ranges.
The ACS723LLCTR-05AB-T has a typical sensitivity of 400 mV/A. The ACS724LLCTR-20AU-T has a typical sensitivity of 200 mV/A. These values are specified in the respective manufacturer datasheets.
No. The ACS724LLCTR-20AU-T is a unidirectional sensor designed to measure current in one direction only. The ACS723LLCTR-05AB-T is bidirectional and can measure current flowing in both directions.
Both the ACS723LLCTR-05AB-T and ACS724LLCTR-20AU-T operate from a single 5 V supply. The typical supply voltage is 5.0 V, with an operating range specified in the datasheets.
Both devices provide basic isolation with a rated isolation voltage of 2.1 kV RMS for 1 minute, as specified in the Allegro MicroSystems datasheets. This allows high-side current sensing in applications requiring galvanic isolation.
The ACS723LLCTR-05AB-T is better suited for low-current measurement because its 5 A full-scale range and 400 mV/A sensitivity provide higher resolution for small currents compared to the ACS724LLCTR-20AU-T, which has a 20 A range and 200 mV/A sensitivity.
Yes. Both the ACS723LLCTR-05AB-T and ACS724LLCTR-20AU-T are specified for an operating temperature range of -40 °C to 125 °C, as stated in their respective datasheets.