AD623AR
Analog Devices Inc.
- Lifecycle
- Active
- Stock
- 7097 PCS
- Package
- SOIC-8
- Series
- Linear - Amplifiers - Instrumentation, OP Amps, Buffer Amps
This in-depth comparison of the AD623AR and AD623ARZ provides valuable insights into their specifications and key features. We cover important factors in detail, including RoHS compliance, REACH status, series, mounting style, package type, and other relevant characteristics. Presenting the differences side by side simplifies component selection, making it easier for you to select the best option for your specific application.
Replacement verdict
The AD623ARZ and AD623AR are functionally equivalent instrumentation amplifiers sharing the same core specifications, package, and pinout, with the AD623ARZ differing only in its RoHS-compliant, lead-free construction. The AD623ARZ is a suitable functional replacement candidate for the AD623AR in most applications, provided that lead-free (Pb-free) solder processing and RoHS compliance are acceptable for the target design.
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | AD623ARZ | AD623AR | Why it matters |
|---|---|---|---|
| Number of Channels | 1 | 1 | Both are single-channel instrumentation amplifiers, so channel count is functionally equivalent. |
| Supply Voltage Range | 2.7 V to 12 V (single supply); ±2.7 V to ±6 V (dual supply) | 2.7 V to 12 V (single supply); ±2.7 V to ±6 V (dual supply) | Identical supply range means either part can operate in the same power rail configuration. |
| Gain Range | 1 to 1000 (set by single external resistor) | 1 to 1000 (set by single external resistor) | Same programmable gain range allows identical signal conditioning behavior. |
| Input Offset Voltage (max) | 200 µV | 200 µV | Matching offset voltage ensures comparable DC accuracy in precision measurement circuits. |
| Input Bias Current (max) | 25 nA | 25 nA | Same bias current affects input loading and error similarly in high-impedance sensor interfaces. |
| Gain Bandwidth Product | 800 kHz (G = 1) | 800 kHz (G = 1) | Identical bandwidth supports the same frequency response and settling behavior. |
| Common-Mode Rejection Ratio (G = 10) | 100 dB | 100 dB | Same CMRR ensures equivalent rejection of common-mode noise in differential measurements. |
| Operating Temperature Range | -40 °C to +85 °C | -40 °C to +85 °C | Identical temperature range means both parts suit the same environmental conditions. |
| Package / Mounting | 8-Lead SOIC (RoHS-compliant, Pb-free) | 8-Lead SOIC (leaded, non-RoHS) | The Z suffix denotes RoHS/Pb-free compliance; this affects regulatory compliance and solder process compatibility, though footprint is identical. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | AD623AR | AD623ARZ |
|---|---|---|
| Part Status | Obsolete | Active |
| Amplifier Type | Instrumentation | Instrumentation |
| Number of Circuits | 1 | 1 |
| Output Type | Rail-to-Rail | Rail-to-Rail |
| Slew Rate | 0.3V/µs | 0.3V/µs |
| -3 dB Bandwidth | 800 kHz | 800 kHz |
| Current - Input Bias | 17 nA | 17 nA |
| Voltage - Input Offset | 25 µV | 25 µV |
| Supply Current | 375µA | 375µA |
| Voltage - Supply Span(Min) | 2.7 V | 2.7 V |
| Voltage - Supply Span(Max) | 12 V | 12 V |
| Operating Temperature | -40°C ~ 85°C | -40°C ~ 85°C |
| Mounting Type | Surface Mount | Surface Mount |
The AD623ARZ and AD623AR are both instrumentation amplifiers from Analog Devices in an 8-lead SOIC package. The primary difference is the package/ordering suffix: the "Z" suffix in AD623ARZ denotes a RoHS-compliant, lead-free (Pb-free) package, while the AD623AR is the non-RoHS (leaded) version. Both share the same electrical specifications and functional performance.
Yes. Both parts are the same AD623 instrumentation amplifier die and share identical electrical specifications, including gain range (1 to 1000 set by a single external resistor), supply range, offset voltage, and CMRR. The only documented difference is the RoHS/lead-free package finish indicated by the "Z" suffix.
Yes, in most cases. Both are 8-lead SOIC devices with the same pinout and identical electrical performance, so the AD623ARZ can replace the AD623AR on an existing PCB. The AD623ARZ is the RoHS-compliant version, so designs requiring lead-free compliance should use the AD623ARZ.
Both the AD623ARZ and AD623AR are supplied in an 8-lead SOIC (Small Outline Integrated Circuit) package, designated as the "R" package by Analog Devices. The package dimensions and pin assignments are identical between the two variants.
Both devices are single-resistor-programmable instrumentation amplifiers with a gain range of 1 to 1000. Gain is set by a single external resistor connected between the RG pins, following the manufacturer-specified gain equation G = 1 + (100 kΩ / RG).
No. Both devices operate from a single supply of 2.7 V to 12 V or dual supplies of ±2.7 V to ±6 V, as specified in the Analog Devices datasheet. The supply requirements are identical for both the RoHS and non-RoHS variants.
The AD623ARZ should be selected for lead-free (Pb-free) and RoHS-compliant manufacturing. The "Z" suffix indicates the RoHS-compliant package finish. The AD623AR is the non-RoHS version and is not intended for lead-free assembly processes.