ADM3050EBRIZ vs ADM3076EARZ

This in-depth comparison of the ADM3050EBRIZ and ADM3076EARZ provides valuable insights into their specifications and key features. We cover important factors in detail, including RoHS compliance, REACH status, series, mounting style, package type, and other relevant characteristics. Presenting the differences side by side simplifies component selection, making it easier for you to select the best option for your specific application.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The ADM3076EARZ and ADM3050EBRIZ are not drop-in replacements for one another. Although both are Analog Devices isolated RS-485 transceivers, they differ in isolation technology, data rate, package footprint, and channel configuration, so a direct board-level substitution is not possible without design changes and revalidation.

Different isolation technology Different data rate Different package footprint Different channel configuration

Parts at a glance

Part A

ADM3050EBRIZ

Analog Devices Inc.

Lifecycle
Active
Stock
5255 PCS
Package
SOIC-8
Series
Interface - Drivers, Receivers, Transceivers
Part B

ADM3076EARZ

Analog Devices Inc.

Lifecycle
Active
Stock
5876 PCS
Package
SOIC-14
Series
Interface - Drivers, Receivers, Transceivers

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADM3076EARZ ADM3050EBRIZ Why it matters
Protocol / Interface Type RS-485 / RS-422 (half-duplex transceiver) CAN FD transceiver (ISO 11898) These devices serve entirely different serial bus protocols, so they are not functionally interchangeable in a given network.
Data Rate Up to 16 Mbps Up to 12 Mbps (CAN FD) Maximum supported bus speed determines whether the part meets the timing requirements of the target network.
Number of Drivers / Receivers 1 driver / 1 receiver 1 driver / 1 receiver Both are single-channel transceivers, but the channel count alone does not make them substitutable across protocols.
Supply Voltage 3.0 V to 3.6 V (3.3 V nominal) 4.5 V to 5.5 V (5 V nominal) Different supply rails mean the parts cannot drop into the same power domain without redesign.
Isolation Non-isolated Galvanically isolated (5 kV rms) Isolation affects safety, ground-loop immunity, and whether external isolators are required in the design.
Duplex Mode Half-duplex Half-duplex (CAN bus) Duplex configuration must match the bus topology and cabling of the intended application.
Package 8-lead SOIC (R-8) 20-lead SOIC_W (RI-20) Footprint and pin count differences prevent direct board-level replacement.
Operating Temperature Range -40 °C to +85 °C -40 °C to +125 °C The wider temperature range of the CAN part suits harsher environments, while the RS-485 part is limited to industrial-standard ranges.
Fail-Safe Receiver Yes (open/short fail-safe) Yes (bus fault protection) Fail-safe behavior ensures a defined logic state during idle or fault conditions, but the mechanisms differ by protocol.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADM3050EBRIZ ADM3076EARZ
Series iCoupler® -
Part Status Active Active
Type Transceiver, Isolated Transceiver
Protocol CAN RS422, RS485
Number of Drivers/Receivers 1/1 1/1
Receiver Hysteresis 150 mV 100 mV
Data Rate 12Mbps 16Mbps
Voltage - Supply 0.5V ~ 6V 3V ~ 3.6V
Operating Temperature -40°C ~ 125°C -40°C ~ 85°C
Mounting Type Surface Mount Surface Mount
Duplex - Full

Frequently asked questions

What are the primary functional differences between the ADM3076EARZ and the ADM3050EBRIZ?

The ADM3076EARZ is a ±15 kV ESD protected, 3.3 V, full-duplex RS-485/RS-422 transceiver in an 8-lead SOIC package. The ADM3050EBRIZ is a 5 kV rms isolated CAN FD transceiver with an integrated isolated DC-to-DC converter, housed in a 20-lead SOIC_W package. They serve different bus protocols (RS-485 vs. CAN FD) and are not functionally interchangeable.

Are the ADM3076EARZ and ADM3050EBRIZ pin-to-pin or package compatible?

No. The ADM3076EARZ uses an 8-lead SOIC (R-8) package, while the ADM3050EBRIZ uses a 20-lead SOIC_W (R-20) package. Pin counts, pin functions, and PCB land patterns differ, so neither part can be dropped into the other's footprint.

What data rates do the ADM3076EARZ and ADM3050EBRIZ support?

The ADM3076EARZ is specified for data rates up to 16 Mbps over RS-485/RS-422. The ADM3050EBRIZ supports CAN FD data rates up to 5 Mbps. The applicable rate depends on the bus protocol and network topology in the target design.

How do the isolation and ESD ratings of the two devices compare?

The ADM3076EARZ provides ±15 kV ESD protection on the RS-485 bus pins but does not include galvanic isolation. The ADM3050EBRIZ provides 5 kV rms isolation per UL 1577 and CSA, with an integrated isolated DC-to-DC converter for the isolated side. The two parts address different safety and grounding requirements.

What supply voltages do the ADM3076EARZ and ADM3050EBRIZ require?

The ADM3076EARZ operates from a single 3.3 V supply. The ADM3050EBRIZ operates from a 5 V supply on the logic side and generates an isolated supply for the CAN bus side through its integrated DC-to-DC converter. Power architecture and decoupling requirements therefore differ between the two parts.

Can the ADM3076EARZ be used as a substitute for the ADM3050EBRIZ in a CAN FD network?

No. The ADM3076EARZ is an RS-485/RS-422 transceiver and does not implement the CAN or CAN FD protocol, nor does it provide isolation. The ADM3050EBRIZ is a dedicated isolated CAN FD transceiver. Substitution would require a protocol change and is not supported by the datasheets.

What are the typical applications for each device?

The ADM3076EARZ is typically used in industrial RS-485/RS-422 networks, building automation, and motor control buses requiring full-duplex communication. The ADM3050EBRIZ is intended for isolated CAN FD networks in industrial, automotive, and medical systems where galvanic isolation and higher-layer protocol compliance are required.