ADS1254E
Texas Instruments
- Lifecycle
- Active
- Stock
- 4308 PCS
- Package
- SSOP-20
- Series
- Data Acquisition - Analog to Digital Converters (ADC)
This in-depth comparison of the ADS1254E and ADS1241EG4 provides valuable insights into their specifications and key features. We cover important factors in detail, including RoHS compliance, REACH status, series, mounting style, package type, and other relevant characteristics. Presenting the differences side by side simplifies component selection, making it easier for you to select the best option for your specific application.
Replacement verdict
The ADS1254E and ADS1241EG4 are both 24-bit delta-sigma ADCs, but they differ in resolution architecture, input channel configuration, package footprint, and interface timing, so the ADS1241EG4 cannot be used as a direct drop-in substitute for the ADS1254E without redesign and validation.
Texas Instruments
Texas Instruments
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADS1254E | ADS1241EG4 | Why it matters |
|---|---|---|---|
| Resolution (bits) | 24 | 24 | Both are 24-bit delta-sigma ADCs, so resolution alone does not differentiate them for substitutability. |
| Number of input channels | 4 (single-ended) | 8 (single-ended) / 4 (differential) | Channel count determines how many signals can be measured; the ADS1241 offers more inputs, affecting system architecture. |
| Maximum sample rate (SPS) | 20k | 1k | Sample rate limits the bandwidth of signals that can be captured; the ADS1254 is much faster, so it is not a drop-in for high-speed needs. |
| Interface type | SPI (serial) | SPI (serial) | Both use a serial SPI interface, simplifying digital-side compatibility between the two parts. |
| Supply voltage (analog) | 5 V | 2.7 V to 5.25 V | The wider analog supply range of the ADS1241 allows lower-voltage operation, while the ADS1254 requires a fixed 5 V rail. |
| PGA / gain stages | No integrated PGA | Integrated PGA (gain 1 to 128) | An integrated PGA allows direct amplification of small signals; the ADS1254 lacks this, requiring external amplification. |
| Package | SSOP-20 | SSOP-28 | Different package footprints and pin counts prevent direct board-level substitution without layout changes. |
| Operating temperature range | -40°C to +85°C | -40°C to +85°C | Identical temperature ratings mean both suit the same industrial environments. |
| Input type | Single-ended | Differential / single-ended | Differential inputs improve noise rejection; the ADS1241 supports them while the ADS1254 is single-ended only. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADS1254E | ADS1241EG4 |
|---|---|---|
| Supplier | - | Texas Instruments |
| Part Status | Active | Discontinued at Digi-Key |
| Number of Bits | 24 | 24 |
| Sampling Rate(Per Second) | 20k | 15 |
| Number of Inputs | 4 | 8 |
| Input Type | Differential | Differential, Single Ended |
| Data Interface | SPI | SPI |
| Configuration | MUX-ADC | MUX-PGA-ADC |
| Number of A/D Converters | 1 | 1 |
| Architecture | Sigma-Delta | Sigma-Delta |
| Reference Type | External | External |
| Voltage - Supply, Analog | 5V | 2.7V ~ 3.3V, 5V |
| Voltage - Supply, Digital | 1.8V ~ 3.6V | 2.7V ~ 5.25V |
| Features | - | PGA |
| Operating Temperature | -40°C ~ 85°C | -40°C ~ 85°C |
The ADS1254E is a 24-bit, 4-channel delta-sigma ADC with a maximum data rate of 19.2 kSPS, housed in a 20-pin SSOP package. The ADS1241EG4 is a 24-bit, 8-channel delta-sigma ADC with a maximum data rate of 1.2 kSPS, housed in a 28-pin SSOP package. The ADS1241EG4 integrates a PGA and offers more input channels, while the ADS1254E provides a higher sampling rate.
No. The ADS1254E uses a 20-pin SSOP package, while the ADS1241EG4 uses a 28-pin SSOP package. The different pin counts and pin functions prevent direct PCB footprint compatibility.
No. Beyond package differences, the two devices differ in channel count (4 vs. 8), maximum data rate (19.2 kSPS vs. 1.2 kSPS), and integrated features such as the PGA in the ADS1241EG4. A direct substitution would require redesign of the PCB layout, input signal chain, and firmware configuration.
The ADS1254E offers a higher maximum data rate of 19.2 kSPS, compared to 1.2 kSPS for the ADS1241EG4. The ADS1254E is therefore better suited for applications requiring faster sampling, while the ADS1241EG4 targets lower-speed, higher-resolution multi-channel measurements.
Yes. The ADS1241EG4 integrates a PGA, allowing direct connection of low-level sensors without external amplification. The ADS1254E does not include an integrated PGA, so external signal conditioning may be required for low-level inputs.
The ADS1254E provides 4 input channels, while the ADS1241EG4 provides 8 input channels. The ADS1241EG4 is preferable for multi-channel measurement systems, whereas the ADS1254E suits applications with fewer input channels but higher throughput requirements.
The ADS1254E is supplied in a 20-pin SSOP package, and the ADS1241EG4 is supplied in a 28-pin SSOP package. The additional pins on the ADS1241EG4 accommodate the extra input channels and integrated PGA functionality.