ADS1230IPW
Texas Instruments
- Lifecycle
- Active
- Stock
- 2859 PCS
- Package
- TSSOP-16
- Series
- Data Acquisition - Analog to Digital Converters (ADC)
This in-depth comparison of the ADS1230IPW and ADS1263IPW provides valuable insights into their specifications and key features. We cover important factors in detail, including RoHS compliance, REACH status, series, mounting style, package type, and other relevant characteristics. Presenting the differences side by side simplifies component selection, making it easier for you to select the best option for your specific application.
Replacement verdict
The ADS1263IPW and ADS1230IPW are not drop-in replacements for one another. The ADS1263IPW is a higher-resolution, higher-channel-count delta-sigma ADC with an integrated PGA and additional features, while the ADS1230IPW is a simpler, lower-resolution single-channel device. They differ in resolution, channel count, package pinout, and feature set, so a direct substitution is not feasible without redesign.
Texas Instruments
Texas Instruments
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADS1263IPW | ADS1230IPW | Why it matters |
|---|---|---|---|
| Resolution (bits) | 32 | 20 | Higher resolution enables detection of smaller signal changes, which is critical for precision measurement applications. |
| Number of input channels | 10 (5 differential / 10 single-ended) | 1 differential | More channels allow multiplexed measurement of multiple sensors with a single ADC, reducing component count. |
| Maximum sample rate | 38.4 kSPS | 80 SPS | Higher sample rates support faster-changing signals and higher-throughput data acquisition systems. |
| Interface type | SPI | SPI | Both use SPI, so the digital host interface is compatible, but the protocol details and register maps differ. |
| Integrated PGA | Yes (gains 1 to 32) | Yes (gains 1, 2, 64, 128) | A PGA amplifies low-level sensor signals before conversion; available gain settings affect achievable input range and noise. |
| Integrated voltage reference | Yes (2.5 V) | No (external reference required) | An internal reference simplifies design and reduces external components; absence requires an external reference for ratiometric or absolute measurements. |
| Supply voltage | Analog 5 V; digital 2.7 V to 5.25 V | 2.7 V to 5.3 V | Supply requirements determine power-rail compatibility and whether level shifting or additional regulators are needed. |
| Package | TSSOP-28 | TSSOP-16 | Different package footprints and pin counts mean the two parts are not drop-in compatible on the same PCB layout. |
| Operating temperature range | -40 °C to +125 °C | -40 °C to +85 °C | A wider temperature range supports harsher environments and provides more margin in industrial applications. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADS1230IPW | ADS1263IPW |
|---|---|---|
| Part Status | Active | Active |
| Number of Bits | 20 | 32 |
| Sampling Rate(Per Second) | 80 | 38k |
| Number of Inputs | 1 | 5, 10 |
| Input Type | Differential, Single Ended | Differential, Single Ended |
| Data Interface | SPI | SPI |
| Configuration | PGA-ADC | MUX-PGA-ADC |
| Number of A/D Converters | 1 | 1 |
| Architecture | Sigma-Delta | Sigma-Delta |
| Reference Type | External | External, Internal |
| Voltage - Supply, Analog | 2.7V ~ 5.3V | 5V |
| Voltage - Supply, Digital | 2.7V ~ 5.3V | 2.7V ~ 5.25V |
| Features | PGA | PGA, Temperature Sensor |
| Operating Temperature | -40°C ~ 85°C | -40°C ~ 125°C |
The ADS1263IPW is a 32-bit, 38-kSPS delta-sigma ADC with an integrated PGA, dual excitation current sources, a 24-bit auxiliary ADC, and a precision voltage reference. The ADS1230IPW is a 20-bit, 80-SPS delta-sigma ADC with an on-chip PGA and a single differential input channel, designed primarily for weigh-scale and bridge-sensor applications. The ADS1263 offers higher resolution, faster output data rates, more input channels, and additional on-chip peripherals compared with the ADS1230.
No. Both devices are offered in a TSSOP-20 package (PW suffix), but their pin functions and internal architectures differ. The ADS1263IPW provides multiple analog inputs, reference pins, and auxiliary ADC connections that are not present on the ADS1230IPW. A direct drop-in replacement is not possible; the PCB layout and pin assignments must be reviewed against each device's datasheet.
The ADS1263IPW supports output data rates up to 38 kSPS in its main ADC path. The ADS1230IPW supports a fixed output data rate of 80 SPS (10 SPS in the slower mode). The ADS1263 is therefore suitable for higher-bandwidth signal acquisition, while the ADS1230 targets low-speed, high-resolution weigh-scale measurements.
The ADS1263IPW provides 32-bit resolution on its primary ADC and includes a 24-bit auxiliary ADC. The ADS1230IPW provides 20-bit resolution. Both incorporate a low-noise PGA, but the ADS1263 offers lower noise density and higher effective resolution at comparable gains, making it better suited for precision measurement applications requiring finer resolution than the ADS1230 can deliver.
Yes. Both the ADS1263IPW and ADS1230IPW integrate a programmable gain amplifier and an on-chip voltage reference. The ADS1263IPW additionally provides dual matched excitation current sources and a precision reference with specified drift, which supports ratiometric bridge-sensor measurements. The ADS1230IPW includes a PGA and internal reference but does not provide the same excitation current source features.
The ADS1263IPW operates from an analog supply of 5 V (with a digital supply of 2.7 V to 5.25 V) and typically consumes approximately 13 mW in normal operation. The ADS1230IPW operates from a single 2.7 V to 5.3 V supply and typically consumes about 1.5 mW. The ADS1230 is therefore better suited to low-power, battery-operated designs, while the ADS1263 trades higher power for increased functionality and speed.
Both devices are used in bridge-sensor signal chains, but the ADS1230IPW was specifically designed for weigh-scale applications with its 20-bit resolution, 80-SPS rate, and low power consumption. The ADS1263IPW is also suitable for precision bridge measurements and adds higher resolution, faster data rates, dual excitation current sources, and an auxiliary ADC, which can simplify multi-sensor or temperature-compensated designs. Selection depends on the required resolution, speed, and system-level feature set.
No, not as a direct replacement. The ADS1230IPW has lower resolution (20-bit vs 32-bit), a lower maximum data rate (80 SPS vs 38 kSPS), fewer input channels, and different pin functions. Replacing an ADS1263IPW with an ADS1230IPW would require redesign of the analog front end, PCB layout, and firmware, and would reduce measurement resolution and throughput. The substitution should only be considered after validating all system requirements against the ADS1230IPW datasheet.