OPA4192IDR vs OPA4130UA

This in-depth comparison of the OPA4192IDR and OPA4130UA provides valuable insights into their specifications and key features. We cover important factors in detail, including RoHS compliance, REACH status, series, mounting style, package type, and other relevant characteristics. Presenting the differences side by side simplifies component selection, making it easier for you to select the best option for your specific application.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Parts at a glance

Part A

OPA4192IDR

Texas Instruments

Lifecycle
Active
Stock
1890 PCS
Series
Linear - Amplifiers - Instrumentation, OP Amps, Buffer Amps
Part B

OPA4130UA

Texas Instruments

Lifecycle
Active
Stock
3667 PCS
Package
SOIC-14
Series
Linear - Amplifiers - Instrumentation, OP Amps, Buffer Amps

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification OPA4192IDR OPA4130UA
Supplier - Rochester Electronics, LLC
Part Status Active Active
Amplifier Type General Purpose J-FET
Number of Circuits 4 4
Slew Rate 20V/µs 2V/µs
Gain Bandwidth Product 10 MHz 1 MHz
Current - Input Bias 5 pA 5 pA
Voltage - Input Offset 5 µV 200 µV
Supply Current 1mA (x4 Channels) 530µA (x4 Channels)
Current - Output / Channel 65 mA 18 mA
Voltage - Supply Span(Min) 4.5 V 4.5 V
Voltage - Supply Span(Max) 36 V 36 V
Operating Temperature -40°C ~ 125°C -40°C ~ 85°C
Mounting Type Surface Mount Surface Mount
Series MicroAmplifier™ -
Output Type Rail-to-Rail -