VIPER06LN vs VIPER12ADIP Comparison
This in-depth comparison of the VIPER12ADIP and VIPER06LN provides valuable insights into their specifications and key features. We cover important factors in detail, including RoHS compliance, REACH status, series, mounting style, package type, and other relevant characteristics. Presenting the differences side by side simplifies component selection, making it easier for you to select the best option for your specific application. For more information, refer to their datasheets or contact our sales team for assistance in selecting the right part for your design.
Specifications
Package
DIP-8
DIP-8
Description
IC OFFLINE SWITCH 8DIP
IC OFFLINE SWITCH MULT TOP 7DIP
Series
VIPER™
VIPer™ plus
Part Status
Obsolete
Active
Output Isolation
Non-Isolated
Either
Internal Switch(s)
Yes
Yes
Voltage - Breakdown
730V
800V
Voltage - Start Up
14.5 V
13 V
Voltage - Supply (Vcc/Vdd)
9V ~ 38V
11.5V ~ 23.5V
Frequency - Switching
60kHz
60kHz
Power (Watts)
13 W
8 W
Fault Protection
Current Limiting, Over Temperature, Over Voltage
Current Limiting, Open Loop, Over Temperature
Operating Temperature
-40°C ~ 150°C (TC)
-40°C ~ 150°C (TJ)
Topology
-
Buck, Flyback
Duty Cycle
-
70%